Twist in time laminar flow11/30/2023 Coriolis mass flow meters will measure the mass flow rate and actual density accurately irrespective of the nature of the fluid as long as the flow is single phase and the fluid is homogeneous.Consequently, the pressure drop will increase accordingly. The latter holds good for Coriolis meters with straight measuring tubes as well. The cross-section of the tube is normally smaller than the cross-section of the line pipe to increase the velocity (v) in order to create higher Coriolis forces. As soon as the pressure recovers above the vapour pressure the bubbles impode.Ĭavitation will cause the meter to malfunction and this should be avoided at all times. Consequently, liquids near boiling point could introduced cavitation as the pressure across the meter drops below the vapour pressure of the liquid (forming of vapour bubbles). ‘U’ and ‘Ω’ shaped coriolis meters cause pressure drop as the flow is increased, resulting in permanent pressure loss.Theoretically, Coriolis force, Fc= 2*m*w*V This twist results in a phase difference (time lag) between the inlet side and the outlet side and this phase difference is directly affected by the mass passing through the tube.Īn advantage of Coriolis flow meters is that it measures the mass flow rate directly which eliminates the need to compensate for changing temperature, viscosity, and pressure conditions.Īlso See: Coriolis Mass Flow Meter AnimationĪ more recent single straight tube design is available to measure some dirty and/or abrasive liquids that may clog the older U-shaped design.įor working properly, a minimum gas density of 4.5 kg/m3 is required. When the tube is moving downward during the second half of the vibration cycle, it twists in the opposite direction. On the opposite side, the liquid flowing out of the meter resists having its vertical motion decreased by pushing up on the tube. When an oscillating excitation force is applied to the tube causing it to vibrate, the fluid flowing through the tube will induce a rotation or twist to the tube because of the Coriolis acceleration acting in opposite directions on either side of the applied force.įor example, when the tube is moving upward during the first half of a cycle, the fluid flowing into the meter resists being forced up by pushing down on the tube. The flow is guided into the U-shaped tube. A Coriolis meter is shown in the figure below: This measured information is further transferred to the electronics unit where it gets transformed to a voltage proportional to mass flow rate. This resulting phase shift which is directly proportional to the liquid mass flow rate is measured with the help of sensors. This added vibration element results in a phase shift or twist in few parts of the tubes. Coriolis forces will then deform the tube and a further vibration component gets added to the already oscillating tube. In this meter unit, the liquid passes through a U-shaped tube which vibrates in an angular harmonic oscillation. These types of meters exist in variety of designs. Hence, a Coriolis meter operates in linear fashion. Since mass does not change, no adjustments are needed for varying fluid characteristics. Coriolis meters are considered to be true mass meters since they tend to measure the mass rate of flow directly while other flow meter technologies measure volumetric flow. Another type available is thermal type mass flow meters Coriolis Mass Flow MeterĪ Coriolis meter works on Coriolis Effect, hence it is named so. However, the most widely used type is the Coriolis meter. There are numerous types of mass flow meters available in the industry. In all these processes, accurate measurement of flow is the prerequisite. Mass flow meters are the types of flow meters which are mainly employed in mass-related processes such as chemical reactions, heat transfer, etc.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |